Quick answer: A radon fan has to sit outside the living space. EPA's Consumer's Guide says the fan must not be located in or below a livable area, so it is installed in an unconditioned space such as an attic or garage, or outdoors on an exterior wall using a fan rated for exterior use. The exhaust must vent above the roof surface, at least 10 feet above the ground, and at least 10 feet from windows, doors or other openings unless it is at least 2 feet above them. In Cheyenne, attic and garage fans are protected from wind and snow and are usually quieter inside the home; exterior fans keep the pipe out of the house but are exposed to cold, so the pipe and condensation must be planned for freezing weather.
Every active radon system has the same parts: a suction point under the slab or in the crawl space, a pipe, a fan and an exhaust that vents above the roof. Where the fan sits decides the route of the pipe through or around your home. In Cheyenne and the rest of Laramie County, the choice also has to account for long cold spells, strong wind and drifting snow.
The rules every location must meet
EPA's Consumer's Guide to Radon Reduction lists basic installation requirements, and refers to the ASTM E2121 standard for homes:
- The fan must not be located in or below a livable area. It is installed in unconditioned space.
- If the fan is outside, it must be rated for exterior use under local building codes.
- The exhaust must vent above the roof surface and 10 feet or more above the ground, and at least 10 feet from windows, doors or other openings that could let radon back in, unless it is at least 2 feet above them.
- Electrical work must follow local codes, and the system must be labeled and have a warning device.
The reason for the fan rule is simple. The pipe on the exhaust side of the fan is under positive pressure. If a joint ever leaks, you want that leak in an attic or outdoors, not in a bedroom or basement.
Option 1: attic fan
The pipe runs from the suction point up through a closet or chase, into the attic, through the fan and out the roof.
- Pros: little is visible outside, the fan is sheltered from wind and snow, and the exhaust exits through the roof by the shortest path.
- Cons: it needs an interior path such as a closet, so some finish work is involved. In a cold attic, the pipe may need insulation to limit condensation freezing.
Option 2: garage fan
The suction point is often in or near the garage, with the pipe going up through the garage ceiling into the attic above and out the roof. An attached garage is unconditioned, so the fan can sit there.
- Pros: very little visible inside the home, easy service access, sheltered from weather.
- Cons: it only works if a good suction point and a path to the roof exist on the garage side of the house. Some fan noise can carry into rooms above the garage.
Option 3: exterior fan
The pipe exits through a rim joist or wall near the suction point, the fan mounts on the outside wall, and the pipe runs up the side of the house to above the roof edge.
- Pros: nothing runs through the living space, which is helpful in a finished home. Service is easy.
- Cons: the pipe is visible (it can be painted or boxed in where allowed), and the fan and exhaust are exposed to Wyoming cold, wind and snow. Condensation can freeze at the top of the pipe in long cold snaps, and drifting snow can bury a low fan. Good designs slope pipe to drain condensation, keep the fan above typical drift height and use fittings meant for cold climates.
Noise and vibration
Radon fans run continuously. Most of the sound comes from vibration in the pipe and air rushing through it. Rubber couplings, solid pipe supports and a route that avoids bedroom walls all help. An exterior fan keeps motor noise outside but may be audible near patios or open windows.
How we choose a location
- Find the best suction point for the foundation. See slab-on-grade mitigation and basement mitigation.
- Look for a route to the roof through unconditioned space or along the exterior.
- Check exhaust clearances from windows, doors and decks.
- Talk with you about appearance, noise and any HOA rules before anything is drilled.
What affects the quote
We don't publish prices. The fan location affects the quote through the pipe length, how much interior finish work is needed, whether the run goes through an attic or up an exterior wall, electrical access and roof height. Call for a free quote.
Frequently asked questions
Can a radon fan be in the basement?
No. EPA says the fan must not be located in or below a livable area. It goes in an attic, garage or outdoors.
How high does the radon exhaust need to be?
Above the roof surface, at least 10 feet above the ground, and at least 10 feet from windows and doors unless it is at least 2 feet above them.
Is an exterior radon fan OK in Cheyenne winters?
Yes, if it is rated for exterior use and the pipe is planned for condensation and snow. Attic and garage fans are more sheltered.
Which location is quietest?
It depends on the house. Attic and garage fans keep noise out of living space if the pipe avoids bedroom walls; exterior fans keep motor noise outdoors.
Can the fan be moved later?
Usually, yes, though it means rerouting pipe. It is easier to choose well at installation.