Quick answer: Most active radon systems in Cheyenne have a U-tube manometer, a clear tube filled with colored liquid mounted on the suction pipe. When the fan is pulling air from under the slab or crawl space, the liquid sits at two different heights. If the two sides are level, the fan is not creating suction, usually because it is off, unplugged, tripped or failed. A reading that is uneven but has changed a lot from the installer's mark can point to a blocked pipe, a cracked joint or a change under the slab. The gauge shows that the fan is moving air; it does not measure radon. EPA requires a warning device on every active system, recommends checking it regularly and suggests retesting at least every two years.
Laramie County is in EPA's highest radon potential zone, and many homes in Cheyenne, the Ranchettes and the surrounding county have an active radon system. Each one should have a warning device. EPA's Consumer's Guide to Radon Reduction says a warning device must be installed to alert you if an active system stops working properly, and lists examples: a liquid gauge, a sound alarm, a light indicator, or a dial or needle gauge. The liquid gauge, called a U-tube manometer, is by far the most common.
What the manometer is
A manometer is a U-shaped clear tube about the size of a hand, usually mounted on the vertical radon pipe in the basement, garage or utility room. It holds a small amount of colored liquid. One end connects to the inside of the pipe through a small hole; the other end is open to the room. A paper or plastic scale behind the tube shows inches of water column.
How to read it
- Find the two liquid levels. Look at the top of the liquid on each side of the U.
- Compare them. If the fan is running and pulling suction, the liquid is pulled up on the side connected to the pipe and pushed down on the other, so the two sides sit at different heights.
- Read the difference. The scale shows the total difference in inches of water column. Many installers write the starting reading and the date on the pipe label.
- Compare with the installer's mark. What matters most is not the exact number but whether it has changed from the reading when the system was new.
What different readings mean
- Both sides level. The fan is not producing suction. Check that it is plugged in and the breaker or GFCI outlet hasn't tripped. If power is fine and the gauge stays level, the fan has likely failed. See radon fan replacement.
- Uneven, close to the original mark. The fan is running and the system is behaving as it did after installation.
- Much higher suction than before. Something may be restricting airflow, such as ice or a blockage at the exhaust, water collecting in a low spot in the pipe, or a change under the slab.
- Much lower suction than before. Air may be leaking in through a loose fitting, cracked pipe, an unsealed sump lid or new cracks in the slab, or the fan may be wearing out.
- Liquid missing or the tube cracked. The gauge itself needs replacement. The fan may be fine, but you can't tell until the gauge is fixed.
Cheyenne weather and the gauge
Cold, wind and snow can affect a system. Exhaust pipes that run outside can collect frost or ice at the top in long cold snaps, and condensation can freeze in pipe runs through unheated spaces. If your reading jumps or drops during a hard freeze, check the exhaust from the ground for an ice cap and keep the area around an exterior fan clear of drifted snow. See radon mitigation in cold weather.
What the gauge can't tell you
A manometer shows that the fan is moving air from below the foundation. It does not measure radon. A system can show normal suction and still leave radon higher than expected if, for example, a new addition or crawl space was never connected. That's why EPA recommends retesting at least every two years, and after renovations, even when the gauge looks normal. See retesting after mitigation.
A simple monthly habit
- Glance at the gauge when you change the furnace filter or walk past the pipe.
- Write the reading and date on the label once in a while, so you notice slow changes.
- Listen to the fan. A new rattle, hum or grinding sound can mean bearing wear.
- Don't turn the fan off. EPA says it must run continuously for the system to work.
What affects the quote
We don't publish prices. If your manometer reads level or has changed, a service quote depends on what we find: a tripped circuit, a failed fan, a cracked pipe, a missing gauge or a slab that needs more sealing. Call for a free quote and tell us what the gauge shows.
Frequently asked questions
What should my radon manometer read?
There is no single correct number. What matters is that the two sides are uneven and the reading is close to the mark the installer recorded.
Why are both sides of my manometer level?
The fan isn't creating suction. Check power and the breaker first, then call for service.
Does the manometer measure radon?
No. It shows airflow from the fan. Retest to know your radon level.
Can cold weather change the reading?
Yes. Ice or frost at the exhaust or in pipe runs can change suction. Check the exhaust during long cold snaps.
Is a manometer required?
EPA's Consumer's Guide says every active system must have a warning device, and a liquid gauge is one of the listed types.